Full Text (PDF)
Case Report

Outcome of Locking Compression Plates in Humeral Shaft Nonunions with Augmented Stabilization done in Rural Tertiary Care Centre: A Case Report

Preetam Raj Chandran , Preetam Raj Chandran

Author Information

Licence:




Journal of Orthopedic Education 8(2):p 59-62, May-August 2022. | DOI: DOI: http://dx.doi.org/10.21088/joe.2454.7956.8222.7

How Cite This Article:

Preetam Raj Chandran/Outcome of Locking Compression Plates in Humeral Shaft Non-unions with Augmented Stabilization done in Rural Tertiary Care Centre- A Case Report/J Orth. Edu. 2022;8(2):59–62.


Timeline

Received : N/A         Accepted : N/A          Published : N/A

Abstract

Fractures that involve the mid-shaft of the humerus are relatively common. Early surgical correction of such patients helps in early mobilization and improved patient comfort but carries an increased risk of post-operative complications. Such fractures are usually managed by 4.5 mm limited contact dynamic compression plates (DCP). In recent studies, it has been proposed that narrow, longer implants have better mechanical benefits with improvement in handling of fracture fragments and the surrounding soft tissue support. TENS provides a three-point bony fixation, hence retaining adequate bony alignment. This prevent micromotion at the fracture site, thereby improving the callus formation and bony union. As TENS is flexible, insertion is easier than rigid intramedullary implants. Here we present an interesting case of Humerus mid-shaft fracture originally managed with 4.5 mm locking DCP, which later required re-do surgery with Bone grafting and a TENS nail. Keywords: Dynamic compression plate; TENS (Titanium elastic nail system); Humerus fracture.


References

No records found.


About this article


Cite this article

Preetam Raj Chandran/Outcome of Locking Compression Plates in Humeral Shaft Non-unions with Augmented Stabilization done in Rural Tertiary Care Centre- A Case Report/J Orth. Edu. 2022;8(2):59–62.


Licence:




Received Accepted Published
N/A N/A N/A

DOI: DOI: http://dx.doi.org/10.21088/joe.2454.7956.8222.7

Keywords


Article Level Metrics

Last Updated

Tuesday 28 July 2026, 22:10:34 (IST)


1568

Accesses

5
129
00

Citations


NA
NA
NA

Download citation


Article Keywords


Keyword Highlighting

Highlight selected keywords in the article text.


Timeline


Received N/A
Accepted N/A
Published N/A

licence



Access this article



Share