Abstract

Context: The study was conducted to establish a co-relation between Sonoclot parameters and blood and blood product during on-pump cardiac surgeries.

Aims: To estimate the amount of blood and blood
product transfusion and post-operative drain are affected by Sonoclot-guided transfusion therapy.

Settings
and Design: Randomised controlled Study

Methods and Material: Total of 120 patients were randomly assigned
by computer generation to either Sonoclot guided therapy or routine hospital therapy. Patients of either sex undergoing on-pump complex cardiac surgical procedures. Patients having pre-existing hepatic disorders, a renal disease requiring dialysis, and those who received anticoagulant or antiplatelet drugs within one week of surgery were excluded.

Statistical analysis used: Data were analyzed using descriptive statistics to get the frequency distribution & the Independent Sample T-test was used for inter-group Comparison. p-value of <0.05 is considered as statistically significant. SPSS (Statistical Software for Social Sciences) version 20 was used.

Results: The whole blood transfusion in the two groups was non-significant both intra-operative and post-operative period. While a comparison of FFP transfusion during an intra-operative period in Sonoclot group was significant. Platelets were administered in the post-operative period and comparison in the two groups was not significant. A comparison of 24 hr drain output in two groups of patients was non-significant.
Conclusions: It allows the diagnosis of an exact cause of hemostatic abnormality i.e. deficiency of coagulation factors or fibrinogen or platelet function.


References

No records found.


About this article


Cite this article

 

Khan Afroz Shahana M, Vaishali A Mohod, Quazi Mohammed Azhar. Sonoclot Analyzer Guided Transfusion Therapy in
Patients Undergoing On-Pump Cardiac Surgeries. Indian J Anesth Analg. 2020;7(3):703–709.


Licence:




Received Accepted Published
N/A N/A N/A

DOI: http://dx.doi.org/10.21088/ijaa.2349.8471.7320.7

Keywords

Point of care testSonoclotTransfusionOn-pump cardiac surgeries.

Article Level Metrics

Last Updated

Saturday 28 February 2026, 13:42:13 (IST)


1389

Accesses

0
245
00

Citations


NA
NA
NA

Download citation


Article Keywords


Keyword Highlighting

Highlight selected keywords in the article text.


Timeline


Received N/A
Accepted N/A
Published N/A

licence



Access this article



Share