Full Text (PDF)
Original Article

Randomized Controlled Study to Compare Axial Length Measurement using Contact Technique and Immersion Technique in Cataractous Eyes in a Tertiary Care Hospital, Bagalkot

Brijesh A Patil , Brijesh A Patil 1 , Jay Singh B N 2 , Shilly Varghese 3

Author Information

Licence:




Ophthalmology and Allied Sciences 8(2):p 53-57, May-August 2022. | DOI: http://dx.doi.org/10.21088/oas.2454.7816.8222.2

How Cite This Article:

How to cite this article: Brijesh A Patil, Jay Singh B N, Shilly Varghese/Randomized Controlled Study to Compare Axial Length Measurement using Contact and Immersion Technique in Cataractous Eyes in a Tertiary Care Hospital, Bagalkot./ Ophthalmol Allied Sci. 2022;8(2): 53–57.


Timeline

Received : N/A         Accepted : N/A          Published : N/A

Abstract

Purpose: Comparison of contact technique with immersion technique in terms of axial length measurements in cataractous eyes & to compare prediction errors in these eyes as measured after surgery.

Materials & Methods: Randomised control study done in 101 patients from December 2019 to June 2022. IOL Power was calculated using SRK/T formula in both groups. Prediction error was compared along with BCVA in contact and immersion technique.

Results: Postoperatively out of 51 cases 24 cases (47.05%) were in the estimated target refractive group (-0.25 to -1 D) and immersion group showed 49 cases (98%) within the estimated target refractive group (-0.25 to -1D). Mean prediction error in contact group was -0.85 ± 0.74 and immersion group -0.25 ± 0.16 with “p” value of <0.001 which is clinically significant.

Conclusion: There was a significant difference in ocular biometry measurement with the contact and immersion ultrasound technique. Precision of immersion technique is better than contact technique.

Keywords: Axial length measurement; Contact technique; Immersion technique; Prediction error.


References

No records found.


About this article


Cite this article

How to cite this article: Brijesh A Patil, Jay Singh B N, Shilly Varghese/Randomized Controlled Study to Compare Axial Length Measurement using Contact and Immersion Technique in Cataractous Eyes in a Tertiary Care Hospital, Bagalkot./ Ophthalmol Allied Sci. 2022;8(2): 53–57.


Licence:




Received Accepted Published
N/A N/A N/A

DOI: http://dx.doi.org/10.21088/oas.2454.7816.8222.2

Keywords


Article Level Metrics

Last Updated

Sunday 26 July 2026, 11:09:44 (IST)


577

Accesses

6
66
00

Citations


NA
NA
NA

Download citation


Article Keywords


Keyword Highlighting

Highlight selected keywords in the article text.


Timeline


Received N/A
Accepted N/A
Published N/A

licence



Access this article



Share