Full Text (PDF)
Original Article

Comparison of Optic Nerve Head and Retinal Nerve Fibre Layer Thickness Analysis by Spectral Domain OCT

Bhaktee Walawalkar, Resident,Dept of Ophthalmology, Dr. DY Patil Medical College and Hospital, Nerul, Navi Mumbai400706, Maharastra, India. , Sumita Karandikar1 , Priyadarshini Cholera1 , Neha Vyas2 , Bhaktee Walawalkar2

Author Information

Licence:




Ophthalmology and Allied Sciences 3(2):p 55-60, Jul-Dec 2017. | DOI: http://dx.doi.org/10.21088/oas.2454.7816.3217.1

How Cite This Article:


Timeline

Received : N/A         Accepted : N/A          Published : N/A

Abstract

Purpose: The aim of the study was to compare optic nerve head (ONH) and Retinal nerve fibre layer (RNFL) thickness tomographic parameters measured by Spectral Domain (SD) OCT and to identify which measurements are best able to differentiate between normal and glaucomatous eyes in Indian population. Design: Cross sectional prospective diagnostic study. Methods: Participants were recruited from a universitybased clinic. 30 age matched normal and 30 Open angle glaucomatous eyes who full filled the inclusion criteria were selected. All cases were subjected for optic nerve head (ONH) and Retinal nerve fibre layer (RNFL) thickness evaluation with the SD OCT (Carl Zeiss). All parameters were compared with normal eyes. The areas under the receiver operating curves AROC were calculated for each single parameter and then compared. Results: Comparative analysis of SDOCT parameters revealed statistically significant difference in all five RNFL parameters between both the groups. Most of the ONH parameters demonstrated statistically significant difference in glaucoma group when compared with control group. The inferior quadrant (0.976) and average RNFL thickness (0.970) obtained the highest AROC values in open angle glaucoma group. The rim area had the best diagnostic accuracy among the ONH parameters (AROC = 0.951). Conclusion: In the present study, RNFL parameters presented with better discriminatory abilities than ONH parameters in the normal and glaucomatous group. Out of all the RNFL and ONH parameters inferior quadrant RNFL thickness, average RNFL thickness and rim area had the best ability to discriminate between glaucomatous and normal eyes.

Keywords: Optical Coherence Tomography; Retinal Nerve Fiber Layer Thickness; Optic Nerve Head Analysis; Spectral Domain 


References

No records found.


About this article


Cite this article


Licence:




Received Accepted Published
N/A N/A N/A

DOI: http://dx.doi.org/10.21088/oas.2454.7816.3217.1

Keywords


Article Level Metrics

Last Updated

Sunday 26 July 2026, 11:08:17 (IST)


577

Accesses

3
66
00

Citations


NA
NA
NA

Download citation


Article Keywords


Keyword Highlighting

Highlight selected keywords in the article text.


Timeline


Received N/A
Accepted N/A
Published N/A

licence



Access this article



Share