Comparison of Conventional Central Venous Pressure with Peripheral Venous Pressure and External Jugular Venous Pressure in Patients with Sepsis

Suresh Kumar N , Rangadhamaiah Sreenidi1 , Suresh Kumar N2

Author Information

Licence:




Indian Journal of Anesthesia and Analgesia 7(4):p 979-985, July-Aug 2020. | DOI: http://dx.doi.org/10.21088/ijaa.2349.8471.7420.19

How Cite This Article:

Rangadhamaiah Sreenidi, Suresh Kumar N. Comparison of Conventional Central Venous Pressure with Peripheral Venous Pressure and External Jugular Venous Pressure in Patients with Sepsis. Indian J Anesth Analg. 2020;7(4):979–985.
 


Timeline

Received : N/A         Accepted : N/A          Published : N/A

Abstract

Context: Central venous pressures along with other dynamic and static variables are used to guide fluid therapy in patients with sepsis admitted to ICU. However, insertion of central venous catheter is associated with serious complications. We, therefore measured external jugular venous pressure (EJVP), peripheral venous pressure (PVP) and correlated with central venous pressure (CVP) measured by conventional technique and thus technical difficulty and complications can be avoided. Aims: To evaluate the correlation between conventional CVP with EJVP and PVP values in patients with sepsis. Settings and Design: Prospective observational study. Methods and Material: Study done on 54 patients admitted with sepsis requiring fluid resuscitation. CVP, EJVP and PVP measurements were taken using a water column manometer in cm H2O. All the three venous pressures were repeated 3 times following every fluid challenge of 250 ml. Statistical analysis used: Pearson's correlation and Bland–Altman's analysis. Results: The observations were analyzed by dividing the patients into 2 groups on the basis of CVP measurements Group A (CVP ≤ 10) Mean difference between CVP with PVP and EJVP is >2 cm H2O and p value is insignificant. Group B (CVP >10) Mean difference between CVP with PVP and EJVP is <2 cm H2O and p value (p<0.001) is strongly significant. Conclusions: The present study concludes that, there is definite correlation between CVP, EJVP and PVP in a given patient. Further concludes the difference between CVP and EJVP/PVP was minimum (<2 cm H2O) when the CVP was >10 cm H 2O.

 


References

No records found.


About this article


Cite this article

Rangadhamaiah Sreenidi, Suresh Kumar N. Comparison of Conventional Central Venous Pressure with Peripheral Venous Pressure and External Jugular Venous Pressure in Patients with Sepsis. Indian J Anesth Analg. 2020;7(4):979–985.
 


Licence:




Received Accepted Published
N/A N/A N/A

DOI: http://dx.doi.org/10.21088/ijaa.2349.8471.7420.19

Keywords

Central venous pressure; External jugular venous pressure; Peripheral venous pressure; Sepsis.

Article Level Metrics

Last Updated

Tuesday 14 July 2026, 10:56:15 (IST)


5693

Accesses

5
679
00

Citations


NA
NA
NA

Download citation


Article Keywords


Keyword Highlighting

Highlight selected keywords in the article text.


Timeline


Received N/A
Accepted N/A
Published N/A

licence



Access this article



Share