Full Text (PDF)
Original Article

Efficacy of Laryngoscopy and Haemodynamic Response to Endotracheal Intubation: A Comparative Study between Airtraq Optical Laryngoscope and Macintosh Laryngoscope

Raghavendra Babu T., 401, Manasa enclave, GSSV Road, Lakshmipuram, Mysuru-570004, Karnataka, India. , Raghavendra Babu T.1 , Anup N.R.2

Author Information

Licence:




Indian Journal of Anesthesia and Analgesia 4(2):p 708-713, April - June 2017. | DOI: http://dx.doi.org/10.21088/ijaa.2349.8471.4217.16

How Cite This Article:


Timeline

Received : N/A         Accepted : N/A          Published : N/A

Abstract

Background: Laryngoscopy is the most important step in the process of endotracheal intubation for administration of general anaesthesia. Airtraq optical laryngoscope is a new rigid indirect optical device with exaggerated curvature of the blade and an internal arrangement of optical components, a view of the glottis is provided without alignment of oral, pharyngeal and tracheal axes. Objective: To compare the efficacy of laryngoscopy and the haemodynamic response to endotracheal intubation between Airtraq and Macintosh laryngoscopes. Methods: One hundred patients of either sex in the age of 20–60 years under ASA grade I and II with Mallampati grading I and II posted for elective surgery under general anaesthesia were selected for the study. Patients were randomly divided into two groups (n = 50). Induction of anaesthesia was standardized. The efficacy of laryngoscopy was compared according to Cormack and Lehane grading and haemodynamic response to endotracheal intubation were compared. Results: In group A (Airtraq), all 50 (100%) patients had Cormack and Lehane grading I and in group M (Macintosh), 33 (66%) patients had Cormack and Lehane grading I and 17 (36%) patients had Cormack and Lehane grading II ( p = 0.000). In x Group A, mean heart rate increased from 83.54±10.19 bpm prior to intubation to 90.08±9.98 bpm after intubation and mean arterial pressure increased from 91.06±8.16 mmHg prior to intubation to 95.30±8.40 mmHg after intubation. In Group M, mean heart rate increased from 80.94±6.71 bpm prior to intubation to 103.30±7.86 bpm after intubation and mean arterial pressure increased from 91.80±7.70 mmHg prior to intubation to 114.20±6.69 mmHg after intubation (p = 0.000). Conclusion: Airtraq optical laryngoscope provides a better exposure of the glottis when compared to Macintosh laryngoscope while triggering minimum haemodynamic response to endotracheal intubation.

Keywords: Laryngoscopy; Hemodynamics; Airtraq; Macintosh. 


References

No records found.


About this article


Cite this article


Licence:




Received Accepted Published
N/A N/A N/A

DOI: http://dx.doi.org/10.21088/ijaa.2349.8471.4217.16

Keywords


Article Level Metrics

Last Updated

Saturday 07 February 2026, 21:07:03 (IST)


1189

Accesses

1
194
00

Citations


NA
NA
NA

Download citation


Article Keywords


Keyword Highlighting

Highlight selected keywords in the article text.


Timeline


Received N/A
Accepted N/A
Published N/A

licence



Access this article



Share