Full Text (PDF)
Original Article

Comparative Analysis of Dose Variations in Tumour Volumes and Organs at Risk in IMRT Plans for Head-and –Neck, Pelvis and Brain Cancers with Varying Dose Calculation Grid Sizes

Pathak P. , Pathak P. , Guha S. , Vitwekar Vidya , Majumder Sourav , Soni Ashok

Author Information

Licence:




Indian Journal of Cancer Education and Research 2(1):p 5-14, January - June 2014. | DOI:

How Cite This Article:


Timeline

Received : N/A         Accepted : N/A          Published : N/A

Abstract

Aims: The aim of this study was to compare the plan results that were obtained by using different calculation grid sizes ranging from 3mm to 10mm, and the same dose calculation algorithm Pencil Beam (PB), in Intensity Modulated Radiotherapy (IMRT) for different treatment sites Head-And –Neck, Pelvis (Carcinoma Cervix) And Brain Cancers. Introduction: Ever since the advent and development of treatment planning systems, the uncertainty associated with calculation grid size has been an issue. Even to this  day , with highly sophisticated 3D conformal and intensity-modulated radiation therapy (IMRT) treatment planning systems (TPS), dose uncertainty due to grid size is still a concern. Methods and Material: Twelve patients in which four patients of Head-And –Neck, Pelvis And Brain tumours respectively were considered for the study. IMRT Plans were generated for a 6,600cGy, 5,000cGy & 5,400cGy prescribed doses for Head-and–Neck,  Pelvis and  Brain  tumours respectively using Oncentra v 4.3 TPS . For each patient, dose calculation with PB algorithms using dose grid sizes of 3.0 mm, 5.0 mm, and 10.0 mm were performed. Results:  The plans were evaluated as per the ICRU guidelines and dose constraints were maintained as per the  Quantec  guidelines. The dose differences for the varying grid sizes in  Tumour Volumes and Organs at Risk were analyzed and tabulated. Conclusions: Overall, the effect of varying grid size on dose variation appears to be insignificant. However, 3 mm is recommended to ensure acceptable dose calculations, especially in high gradient regions.

Keywords: Dose grid; 2D array; Organs at risk; Intensity-modulated radiotherapy; Dose-volume changes; Head-and-neck cancers.


References

No records found.


About this article


Cite this article


Licence:




Received Accepted Published
N/A N/A N/A

DOI:

Keywords


Article Level Metrics

Last Updated

Friday 31 July 2026, 15:29:16 (IST)


1318

Accesses

4
266
00

Citations


NA
NA
NA

Download citation


Article Keywords


Keyword Highlighting

Highlight selected keywords in the article text.


Timeline


Received N/A
Accepted N/A
Published N/A

licence



Access this article



Share