Abstract

Context: Not many studies have compared the new laryngeal mask airway (LMA) devices with pre-existing ones. We compared ambu auragain LMA with LMA supreme in this study for controlled ventilation under general anaesthesia. Aims: The main aim of this study was to the compare ambu auragain LMA with the LMA supreme for controlled ventilation during general anaesthesia. Material and Methods: 50 patients aged 18 to 50 years of American society of Anaesthesiologists (ASA) grade I and II of either gender, weight 30 to 70 kilogram, with Mallampatti grade -I/II posted for elective surgeries in supine position under general anaesthesia were randomly allocated into two equal groups. Group A (ambu auragain) and group S (LMA supreme). Both groups were compared for numbers of attempts and time taken for insertion of device, ease of insertion of nasogastric tube (NGT), oropharyngeal leak pressure, hemodynamic stability and any side effects or complications. Statistical analysis: The statistical analysis was assessed by unpaired student’s t-test. p<0.05 was considered significant. Result: Both groups were statistically comparable in regard to number of attempts for placement and time of insertion of device, ease of insertion of NGT and haemodynamic stability. Group A had higher oropharyngeal leak pressure 32.0 ± 1.34 compared to Group S 26.0 ± 1.21 (p=0.0001). Conclusion: Ambu auragain can be a better alternative to LMA supreme for controlled ventilation under general anaesthesia due to high oropharyngeal leak pressure.


References

No records found.


About this article


Cite this article

Himanshu Mehta, Tejash H. Sharma, Jayshri Desai. An Observational Study to Compare Ambu Auragain and Supreme Laryngeal Mask Airway for Controlled Ventillation Under Anaesthesia. Indian J Anesth Analg. 2019;6(2):438-442.


Licence:




Received Accepted Published
N/A N/A N/A

DOI: http://dx.doi.org/10.21088/ijaa.2349.8471.6219.11

Keywords

Ambu auragain LMALMA supremeoropharyngeal leak pressurehemodynamic stability.

Article Level Metrics

Last Updated

Saturday 28 February 2026, 11:23:45 (IST)


1389

Accesses

0
245
00

Citations


NA
NA
NA

Download citation


Article Keywords


Keyword Highlighting

Highlight selected keywords in the article text.


Timeline


Received N/A
Accepted N/A
Published N/A

licence



Access this article



Share