Ravi Kumar Chittoria Professor & Head of IT Wing and Telemedicine, Department of Plastic Surgery & Telemedicine, Jawaharlal Institute of Postgraduate Medical Education and Research Institute, Puducherry 605006, India
Nishad K. Senior Resident, Department of Plastic Surgery & Telemedicine, Jawaharlal Institute of Postgraduate Medical Education and Research Institute, Puducherry 605006, India
Neljo Thomas Senior Resident, Department of Plastic Surgery & Telemedicine, Jawaharlal Institute of Postgraduate Medical Education and Research Institute, Puducherry 605006, India
Barath Kumar Singh Senior Resident, Department of Plastic Surgery & Telemedicine, Jawaharlal Institute of Postgraduate Medical Education and Research Institute, Puducherry 605006, India
Jacob Antony Chakiath Senior Resident, Department of Plastic Surgery & Telemedicine, Jawaharlal Institute of Postgraduate Medical Education and Research Institute, Puducherry 605006, India
Address for correspondence: Ravi Kumar Chittoria, Professor & Head of IT Wing and Telemedicine, Department of Plastic Surgery & Telemedicine, Jawaharlal Institute of Postgraduate Medical Education and Research Institute, Puducherry 605006, India E-mail: drchittoria@yahoo.com
This license enables
reusers to distribute, remix, adapt, and build upon the material in any medium
or format for noncommercial purposes only, and only so long as attribution is
given to the creator.
Journal of Emergency and Trauma Nursing
4(1):p 9-12, January-June 2023. | DOI: NA
How Cite This Article:
Nishad K., Neljo Thomas, Ravi Kumar Chittoria, et al./Role of Systemic Coolant as An Adjunct in Laser Assisted Ear Piercing/
Journal of Emergency and Trauma Nursing. 2023;4(1):9–12.
Timeline
Received : December 13, 2022
Accepted : January 15, 2023
Published : June 25, 2023
Abstract
A plastic surgeon's earlobe piercing is a regular office practice. Ear piercing has been described in a variety of ways. We discuss a new method of laser ear piercing that uses a systemic coolant in this publication. After systemic precooling, a 56-year-old female patient had her ear pierced with an Er:YAG laser with a power of 10J/cm2 in continuous mode. Ear piercing using the Er:YAG laser was quick, painless, and highly effective. More precision, minimal stress with less pain, no bleeding due to the coagulation action of the laser, and decreased possibility of infection due to the thermal heat impact of the laser were the benefits we found when using the systemic coolant over conventional approaches.
References
1. Adigun IA, Aderibigbe AB. Earlobe keloids: Emerging cosmetic complication of earpiercing. Nig Q J Hosp Med. 2010;20:97–100.
2. Stirn A. Body piercing: Medical consequences and psychological motivations. Lancet. 2003;361:1205–15.
3. Lamba S, Gupta AK. A novel technique for piercing of ear lobule suited to Indian subcontinent. Indian J Plast Surg. 2013;46:594.
4. Chang YT, Wu JL, Chao JC, Lin CY. The alternative ear-piercing technique by using superpulsed carbon dioxide laser: A comparative study with spring-loaded gun. Eur Arch Otorhinolaryngol. 2012;269:339–43.
5. Azma E, Safavi N. Diode laser application in soft tissue oral surgery. J Lasers Med Sci. 2013;4:206–11.
6. Desiate A, Cantore S, Tullo D, Profeta G, Grassi FR, Ballini A. 980 nm diode lasers in oral and facial practice: Current state of the science and art. Int J Med Sci. 2009;6:358–64.
7. Ishikawa I, Aoki A, Takasaki AA, Mizutani K, Sasaki KM, Izumi Y. Application of lasers in periodontics: True innovation or myth? Periodontol 2000. 2009;50:90–126.
8. Cobb CM. Lasers in periodontics: A review of the literature. J Periodontol. 2006;77:545–64.
10. Luomanen M, Meurman JH, Lehto VP. Extracellular matrix in healing CO 2 laser incision wound. J Oral Pathol. 1987;16:322–31.
11. Van Wijk MP, Kummer JA, Kon M. Ear piercing techniques and their effect on cartilage, a histologic study. J PlastReconstrAesthet Surg. 2008;61(Suppl 1):S104–9.
Data Sharing Statement
There are no additional data available. All raw data and code are available upon request.
Funding
This research received no funding.
Author Contributions
All authors contributed significantly to the work and approve its publication.
Ethics Declaration
This article does not involve any human or animal subjects, and therefore does not require ethics approval.
Acknowledgements
We would like to express our gratitude to the patients, their families, and all those who have contributed to this study.
Conflicts of Interest
No conflicts of interest in this work.
About this article
Cite this article
Nishad K., Neljo Thomas, Ravi Kumar Chittoria, et al./Role of Systemic Coolant as An Adjunct in Laser Assisted Ear Piercing/
Journal of Emergency and Trauma Nursing. 2023;4(1):9–12.
This license enables
reusers to distribute, remix, adapt, and build upon the material in any medium
or format for noncommercial purposes only, and only so long as attribution is
given to the creator.
This license enables
reusers to distribute, remix, adapt, and build upon the material in any medium
or format for noncommercial purposes only, and only so long as attribution is
given to the creator.