Full Text (PDF)
Original Article

Evaluation of Linear Dimensional Accuracy of Conventional Heat Cure Resin and Microwave Cured Resin: A Comparative Study

Pankaj Datta , Pawan Kumar1 , Savita Akki2 , Mahesh Suganna3 , Pankaj Datta4 , Aruna DS5 , Sonia Datta6

Author Information

Licence:




Indian Journal of Dental Education 12(1):p 11-16, Jan-Mar 2019. | DOI: DOI: https://dx.doi.org/10.21088/ijde.0974.6099.12119.2

How Cite This Article:

Pawan Kumar, Savita Akki, Mahesh Suganna et al. Evaluation of Linear Dimensional Accuracy of Conventional Heat Cure Resin and Microwave Cured Resin: A Comparative Study. Indian J Dent Educ. 2019;12(1):11-16.


Timeline

Received : N/A         Accepted : N/A          Published : N/A

Abstract

Objective: The use of microwave energy has been used in various fields of dentistry, medicine and household appliances. Recently microwave energy has been successfully used in dentistry and plethora of articles has been published. Also included in the field of sterilization, disinfection of dental appliances, drying of gypsum product and polymerization of resin. The objective of this study was to compare the linear dimensional accuracy of conventional heat cure resin to microwave cure resin. Method: In this study a standard metal die as per ADA specification NO 12 measuring 65 mm in length,3 mm thickness,10 mm wide was used to plan 30 test specimens. 15 test specimens were prepared from conventional heat cure resin and 15 from microwave cured resin. The specimens were checked and evaluated using digital caliper which has precision of ±0.001 mm. The measurements were compared recorded with standard metal dies. Result and conclusion: Linear dimensional accuracy was checked both between and within the group with the ANOVA test and found that accuracy between the groups was 0.148 and 0.004 within the group of the study. Consequently the liner dimensional accuracy of microwave resin were better-quality and advanced to conventional cure resin with p value of 0.000.

Keywords: Denture Base Resins; Conventional Heat Cure Resin; Microwave Cure Resin; Linear Dimensional Accuracy; Polymerization; Metal Dies.


References

No records found.


About this article


Cite this article

Pawan Kumar, Savita Akki, Mahesh Suganna et al. Evaluation of Linear Dimensional Accuracy of Conventional Heat Cure Resin and Microwave Cured Resin: A Comparative Study. Indian J Dent Educ. 2019;12(1):11-16.


Licence:




Received Accepted Published
N/A N/A N/A

DOI: DOI: https://dx.doi.org/10.21088/ijde.0974.6099.12119.2

Keywords


Article Level Metrics

Last Updated

Monday 19 October 2026, 19:53:21 (IST)


3456

Accesses

6
611
00

Citations


NA
NA
NA

Download citation


Article Keywords


Keyword Highlighting

Highlight selected keywords in the article text.


Timeline


Received N/A
Accepted N/A
Published N/A

licence



Access this article



Share