Full Text (PDF)
Original Article

Comparison of Simultaneously Obtained Central Venous Blood Gas and Arterial Blood Gas Analysis for pH, pCO2, BE and K+ in Patients Presenting to Emergency Medicine and Critical Care Unit

G. Vishwa Reddy, Assistant Professor, Department of Emergency Medicine, Nizam’s Institute of Medical Sciences, Hyderabad - 500082, Telangana State, India. , G. Vishwa Reddy , Kondle Raghu , P.V. Sai Satyanarayana , Ramya Kumari , Ashima Sharma

Author Information

Licence:




Indian Journal of Emergency Medicine 3(1):p 7-14, January - June 2017. | DOI: http://dx.doi.org/10.21088/ijem.2395.311X.3117.1

How Cite This Article:


Timeline

Received : N/A         Accepted : N/A          Published : N/A

Abstract

Objective: This study was done to compare Arterial values of pH , pCO2,B.E, K+ with Central venous values and to establish a correlation between arterial and central venous values of pH , pCO2, B.E, K+ in the clinical management of selected patients in the emergency department. Methods: The study population consisted of 40 critically ill patients in emergency and critical care units. Arterial and Central venous blood gas measurements of pH, pCO2 B.E, K+ were taken. Simultaneously other variables were noted Comparision of mean values of pH , pCO2, B.E , K+ between arterial and central venous was done using t –test. Results: As per the linear regression analysis arterial values of pH , pCO2 B.E, were found to be correlated significantly with central venous values (correlation coefficient r being 0.94 for pH and r =.96 for pCO2, r =.97 for B.E), while arterial and venous values of K+ were found to be poorly correlated (correlation coeffiecient,r =.375 .). Conclusion: Central venous blood gas values of pH, pCO2 B.E can be considered instead of arterial blood gas values in continuous assessment of critically ill patients. As per this study estimation of arterial values of potassium cannot be done based on venous potassium levels. Frequent arterial punctures can be avoided by recording central venous blood gas values in monitoring of critically ill patients.
 


References

No records found.


About this article


Cite this article


Licence:




Received Accepted Published
N/A N/A N/A

DOI: http://dx.doi.org/10.21088/ijem.2395.311X.3117.1

Keywords

Blood Gas Analysis; Venous pH.

Article Level Metrics

Last Updated

Wednesday 17 June 2026, 09:00:09 (IST)


2146

Accesses

3
735
00

Citations


NA
NA
NA

Download citation


Article Keywords


Keyword Highlighting

Highlight selected keywords in the article text.


Timeline


Received N/A
Accepted N/A
Published N/A

licence



Access this article



Share