Full Text (PDF)
Original Article

A Comparative Study between Mac-Coy and Macintosh Blade for Glottis Exposure and Hemodynamic Changes

Vaishali Waindeskar. , Anuka singh1 , Vaishali Waindeskar2 , Sheetal Songir3 , Shrinivas S R4 , Charan Raj SR5

Author Information

Licence:




Indian Journal of Trauma and Emergency Pediatrics 12(3):p 9-14, July – September 2020. | DOI: http://dx.doi.org/10.21088/ijtep.2348.9987.12320.1

How Cite This Article:

Anuka Singh, Vaishali Waindeskar, Sheetal Songir et. al. A Comparative Study between Mac-Coy and Macintosh Blade for Glottis Exposure and Hemodynamic Changes. Indian J Trauma Emerg Pediatr. 2020;12(3):9–14.
 


Timeline

Received : N/A         Accepted : N/A          Published : N/A

Abstract

The aim of laryngoscopy is to obtain good visualization of vocal cords to facilitate smooth endotracheal intubation. Many factors have shown to
influence Laryngoscopic view of vocal cords. These include forward displacement of mandible, prominent or absent teeth, backward displacement of tongue. Difficult Mask Ventilation i.e., Bones. Laryngoscopy and endotracheal intubation trigger major stress
response, in the form of increased catecholaminesleading to tachycardia and hypertension, which may be catastrophic in patients with cardiovascular disease.1,2 Present study was done to evaluate the ease
of intubation and there effect on hemodynamic parameters by using two different laryngoscopy blades. Taking Mallampati grading, Cormack and Lehane grading into consideration the various parameters were studied.The McCoy blade, which is a modification of the Macintosh blade with its levering tip significantly reduces the duration of laryngoscopy, improves the visualization of the larynx. less increase in
hemodynamic parameters during laryngoscopy and intubation, early return of hemodynamic parameters towards baseline following intubation.


Keywords:Mac Coy; Macintosh blade; Laryngoscopy;
Glottic exposure; Hemodynamic changes.
 


References

No records found.


About this article


Cite this article

Anuka Singh, Vaishali Waindeskar, Sheetal Songir et. al. A Comparative Study between Mac-Coy and Macintosh Blade for Glottis Exposure and Hemodynamic Changes. Indian J Trauma Emerg Pediatr. 2020;12(3):9–14.
 


Licence:




Received Accepted Published
N/A N/A N/A

DOI: http://dx.doi.org/10.21088/ijtep.2348.9987.12320.1

Keywords


Article Level Metrics

Last Updated

Monday 27 July 2026, 08:02:22 (IST)


1086

Accesses

2
184
00

Citations


NA
NA
NA

Download citation


Article Keywords


Keyword Highlighting

Highlight selected keywords in the article text.


Timeline


Received N/A
Accepted N/A
Published N/A

licence



Access this article



Share