Advertisement!
Author Information Pack
Editorial Board
Submit article
Special Issue
Editor's selection process
Join as Reviewer/Editor
List of Reviewer
Indexing Information
Most popular articles
Purchase Single Articles
Archive
Free Online Access
Current Issue
Recommend this journal to your library
Advertiser
Accepted Articles
Search Articles
Email Alerts
FAQ
Contact Us
Indian Journal of Dental Education

Volume  3, Issue 3, July - September 2010, Pages 139-142
 

Original Article

The effect of developer age and file thickness on diagnostic accuracy of Kodak insight (F-speed) and Ektaspeed plus (E-speed) films in position assessment of file tip to radiographic apex

A. Dabaghi* M. Lomee** S. Saati***

*Assistant Professor of Oral and Maxillofacial Radiology, Faculty of Dentistry, Ahvaz Jundi Shapur University of Medical Science, **Post Graduated Student of Endodontics, Faculty of Dentistry, Mashhad University of Medical Science, ***Post Graduated

Choose an option to locate / access this Article:
days Access
Check if you have access through your login credentials.        PDF      |
|

Open Access: View PDF

DOI:

Abstract

 Objectives : To determine the effect of developer age and file thickness on diagnostic accuracy of E and F- speed films in position assessment of file tip to radiographic apex., Study design: Endodontic files size 10 and 15 were placed in mandibular first molar and second premolar up to the root apex or 1.5 mm shorter. Ten series of radiographs were made with two types of film: Kodak insight (F-speed film) and Ektaspeed plus (E-speed film) in different positions of file in apex or 1.5 mm short. The films of each series were processed manually on each day, using Champion chemicals. The films were assessed by four endodontists. They rated the position of file tip to radiographic apex using a 3-point confidence scale in the questionnaires (tip to tip, 1.5 mm under, can not diagnose). The diagnostic performance of observers was compared with true diagnosis., Results : Mean Az value of E and F-speed films, that shows the diagnostic accuracy is 0.986 and 0.983 for E and F-speed films respectively, that was not significantly different (P = 0.777). Also diagnostic accuracy of films processed during 10 days was not statistically different (P = 0.726). Assessment of files tip size 10 and 15 in lower molar and premolar canals was not significantly different (P = 0.712)., Conclusion : The performance of the F-speed film was not statistically different from E-speed for assessment of file tip to radiographic apex. Because of less required exposure, we suggest to use Kodak insight (F-speed film) in clinical examination.

Key words: Diagnostic accuracy, Intra oral radiographic film, Working length 


Corresponding Author : A. Dabaghi*