Advertisement!
Author Information Pack
Editorial Board
Submit article
Special Issue
Editor's selection process
Join as Reviewer/Editor
List of Reviewer
Indexing Information
Most popular articles
Purchase Single Articles
Archive
Free Online Access
Current Issue
Recommend this journal to your library
Advertiser
Accepted Articles
Search Articles
Email Alerts
FAQ
Contact Us
Indian Journal of Anatomy

Volume  8, Issue 3, July-September 2019, Pages 197-203
 

Original Article

Morphometric Study of Tricuspid Valve Annulus and Right Ventricular Papillary Muscle: A Cadaveric Study from Marathwada Region

Mukta Pande1, Shivaji Sukre2, Pratima Kulkarni

1Assistant Professor, 2Professor and Head, 3Associate Professor, Department of Anatomy, Government Medical College, Aurangabad, Maharashtra 431004, India.

Choose an option to locate / access this Article:
60 days Access
Check if you have access through your login credentials.        PDF      |
|

Open Access: View PDF

DOI: DOI: http://dx.doi.org/10.21088/ija.2320.0022.8319.10

Abstract

Tricuspid valve complex is commonly involved in various heart diseases like rheumatic heart diseases, congenital cardiac anomalies etc. Studies on Tricuspid valve complex, in Maharashtrians are few; so the present work was undertaken. Thirty five formalin fixed embalmed adult heart obtained by dissecting cadavers allotted to undergraduate students in GMC, Aurangabad, were studied irrespective of gender and cause of death. In present study circumference of tricuspid valve annulus was (mean +/- SD) 10.96 +/- 1.36 cm with range 8.6 cm to 13.6 cm; Diameter at minimum separated points (D1) was in the range of 2 cm to 3.5 cm and diameter measured at maximally separated points (D2) were in range 2.8 cm to 4.4 cm. Occurrence of papillary muscle was noted, anterior and posterior papillary muscle were present in all specimens however septal papillary muscle was absent in 9 out of 35 specimens. Anterior papillary muscle dimensions were noted; mean length for it was 1.224 cm +/- 0.478 cm with range 0.4 cm to 2 cm and mean thickness was 0.488 cm +/- 0.182 cm (range 0.3 cm to 0.9 cm).Knowledge of anatomy of tricuspid valve complex bears importance for operative procedures on tricuspid valve abnormalities. Present study data might be useful for cardiothoracic surgeons for newer surgical techniques like papillotomy, correction of papillary rupture induced tricuspid regurgitation.

Keywords: Anterior papillary muscle; Tricuspid valve.


Corresponding Author : Shivaji Sukre